LUGB series Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle. Adopting advanced differential algorithm along with measurement of isolation, shielding and wave filtering, LUGB series vortex flow meters have the advantages of immunity on vibration and noise. Meanwhile, the liabilities of LUGB series vortex flow meters are well guaranteed by unique sensor packaging technology. Upon receipt, examine your meter for visible damage. The Vortex is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us. Make sure the Vortex flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the Vortex. Refer to the nameplate for your customized product's specification.
2.Technical Data
Measuring system
Application range
(1) Gas; (2) Liquid; (3) Steam
Measured Value
Â
Primary measured value
Flow Rate
Secondary measured value
Volume flow ; (Pressure and Temperature is available for model with compensation)
Â
Design
Features
Â
Modular construction
The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version.
Compact version converter
N Type: Pulse output without local display
A Type: 4-20mA Output without local display
B Type: Local Display; Lithium Battery Power; No Output (Battery Part No.: ER26500)
C Type: Local Display; 24V DC Power; 4-20mA Output; Optional Function:
Backup Power Supply: Lithium Battery
Modbus RS485
Pulse Output
Connection
Â
Flange: DN15-DN300
Wafer: DN15-DN300
Measurement Ratio
Standard - 10:1
Â
Measuring accuracy
Reference conditions
Flow conditions similar to EN 29104
Medium: Water / Gas
Electrical conductivity: ≥ 300 μS/cm
Temperature: +10...+30°C / +50...+86°F
Inlet section: ≥ 10 DN
Operating pressure: 1 bar / 14.5 psig
Flow Meter Accuracy
Â
For Liquid: 1.0% of rate For Gas and Steam: 1.5% of rate
Â
Operating conditions
Temperature
Â
Process temperature
T1 Level: -20...+70°C
T2 Level: -20...+250°C
T3 Level: -20...+350°C
Ambient temperature (all versions)
Standard (with aluminum converter housing):
-10…+55°C
Storage temperature
-20...+70°
Pressure
Â
EN 1092-1
DN200…DN300: PN10
DN100…DN200: PN 16
DN15…DN80: PN 25
Other pressures on request
ASME B16.5
1/2"...8": 150 lb RF
Other pressures on request
JIS
1/2"...8": 10 K
Other pressures on request
Â
Installation conditions
Installation
Take care that flow sensor is always fully filled
For detailed information see chapter "Cautions for Installation"
Flow direction
Forward
Arrow on flow sensor indicates flow direction.
Inlet run
≥ 10 DN
Outlet run
≥ 5 DN
Â
Materials
Sensor housing
SS304
Other materials on request
Flanges
SS304
Other materials on request
Converter Housing
Standard: polyurethane coated die-cast aluminum
Â
Process connections
Flange
Â
EN 1092-1
DN15...300 in PN 6...25
ASME
1/2"…12" in 150 lb RF
JIS
1/2"…12" in 10...20K
Design of gasket surface
RF
Â
Other sizes or pressure ratings on request
Wafer
DN15…DN300
 Measurable Flow Rate Range: Note: The flow range as blow is for reference only. Consult the factory if you have special requirement. Refer to the nameplate or certificate for actual flow range.
Nominal Diameter
Liquid
Gas
(mm)
(in.)
Flow (m3/h)
Flow (m3/h)
15
1/2"
1.2 to 6.2
5 to 25
20
3/4"
1.5 to 10
8 to 50
25
1"
1.6 to 16
10 to 70
40
1-1/2"
2.5 to 25
22 to 220
50
2"
3.5 to 35
36 to 320
65
2-1/2"
6.5 to 65
50 to 480
80
3"
10 to 100
70 to 640
100
4"
15 to 150
130 to 1100
125
5"
25 to 250
200 to 1700
150
6"
36 to 380
280 to 2240
200
8"
62 to 650
580 to 4960
250
10"
140 to 1400
970 to 8000
300
12"
200 to 2000
1380 to 11000
Â
3. Model and Selection
Table 1: Model Selection Guidance for Vortex Flowmeter
Model Suffix Code
Â
Â
Description
LUGB-
Â
Â
Â
Â
Â
Â
Â
Â
Connection
1
Â
Â
Â
Â
Â
Â
Flange
2
Wafer
Fluid
0
Gas
1
Liquid
2
Steam
Diameter
Â
Three Digitals; for example: 010: 10 mm;015: 15 mm; 080: 80 mm;100: 100 mm
Structure
Z
Compact Type
F
Remote Type
Converter
N
No display; 24V DC; Pulse Output
A
No display; 24V DC; 4-20mA Output
B
Local display; Lithium Battery Power; No output
C1
Local display; 24V DC Power; pulse output & RS485 Optional backup power: Lithium Battery
C2
Local display; 24V DC Power; 2 - wire 4- 20mA Output Optional backup power: Lithium Battery
C3
Local display; 24V DC Power; 3 - wire 4- 20mA and pulse Output, with RS485 Optional backup power: Lithium Battery
D
Temperature / Pressure Compensation D1_1:Â Â 24V DC Power, LCD+pulse+2wire 4-20mA; D1_3:Â battery+DC24V power, LCD+ pulse, 3-wire 4-20mA, Modbus RS485 D1_4: DC24V power, 2-wire 4-20mA + Hart; Refer to the photo on cover (Right One)
Explosion Rating
Â
N
Safety Field without Explosion
E
ExdIIBT6
Flange Standard
Â
Â
-DXX
DXX: D06, D10, D16, D25, D40 D06: DIN PN6; D10: DIN PN10 D16: DIN PN16; D25: DIN PN25 D40: DIN PN40
JX: J1, J2, J4 J1: JIS 10K; J2: JIS 20K; J4: JIS 40K
-WF
Wafer Connection; Mating Flange included.
Fluid Temperature
Â
Â
Â
-T1
-20...+70°C
-T2
-20...+250°C
-T3
-20...+350°C
Special requirements
Â
N
If no special requirements.
Model Code: LUGB-2S050ZCN-WF-T2-N Explanation - Wafer Connection; Fluid: Steam; Diameter: 50mm; Compact Type; Converter: 24V DC Power Supply, 4-20mA Output, Local Display; No Explosion; Fluid Temperature: 20…+250°C Â
PTFE Skived Film Tape is the one using PTFE film as base material.
Single surface treated and coated with silicone adhesive with excellent heat
resistance. The tape exhibits superior features such as desirable electrical