Model NO.: WD-AC/S
Application Fields: Chemical
Application Machine: Combination machine
Certification: ISO, CE
Condition: New
Cooling Capacity: 12rt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 2060*1025*1910mm
Total Weight: 1035kg
Trademark: WINDAY
Transport Package: Plywood Box
Specification: CE, ISO9001
Origin: Shanghai
HS Code: 8418699090
Model NO.: WD-AC/S
Application Fields: Chemical
Application Machine: Combination machine
Certification: ISO, CE
Condition: New
Cooling Capacity: 12rt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 2060*1025*1910mm
Total Weight: 1035kg
Trademark: WINDAY
Transport Package: Plywood Box
Specification: CE, ISO9001
Origin: Shanghai
HS Code: 8418699090
Chiller Units For Machining Coolant Systems Flush
Â
Our products as follow:
3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller
Â
The Details of the chiller:
1.The Temperature Range:7ºC to -85ºC. Â
2.Cooling Capacity Range:
1RT to 1000RT
3.52kw to 3520kw
12010Btu to 12010240Btu
3027.2Kal to 3027200Kal
3. The Refrigerant:Â R22/R407c/R410a/R404a/R134a/R507c.
4.We can also produce the chiller according to your requirements.
One Parameter of our water chiller:
Air-cooled chiller parameters(output tem 7ºC)
Model |
 UNIT |
WD- |
 |
3AC/S |
5AC/S |
8AC/S
|
10AC/S
|
12AC/S
|
15AC/S
|
20AC/S
|
25AC/S
|
30AC/S
|
40AC/S
|
Cooling capacity |
Btu |
30026 |
49133 |
87006 |
98948 |
111572 |
140233.2 |
188684 |
223145 |
280466 |
377367 |
RT |
2.5 |
4.1 |
7.2 |
8.3 |
9.3 |
11.7 |
15.7 |
18.6 |
23.4 |
31.5 |
Kw |
8.8 |
14.4 |
25.5 |
29.0 |
32.7 |
41.1 |
55.3 |
65.4 |
82.2 |
110.6 |
×10³Kcal/h |
7.6 |
12.4 |
21.9 |
25.0 |
28.1 |
35.4 |
47.6 |
56.3 |
70.7 |
95.2 |
 Total Power |
KW |
3.1 |
5.2 |
8.1 |
9.5 |
10.9 |
14.4 |
19.3 |
20.5 |
28.6 |
38.0 |
Total Current |
A |
5.7 |
9.6 |
14.8 |
17.3 |
19.9 |
26.3 |
35.3 |
37.6 |
52.3 |
69.5 |
       Compressor |
 Qty |
set |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
2.00 |
2.00 |
2.00 |
Input power |
kw |
2.6 |
4.3 |
7.0 |
7.9 |
8.9 |
12.4 |
16.6 |
17.9 |
24.9 |
33.3 |
 Operation Current |
A |
4.6 |
7.6 |
12.4 |
14.0 |
15.9 |
22.1 |
29.6 |
31.8 |
44.3 |
59.2 |
Condenser |
Type |
Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger |
 |
Fans |
Input power |
kw |
0.19 |
0.42 |
0.38 |
0.84 |
0.84 |
0.84 |
1.14 |
1.14 |
1.50 |
2.52 |
Input Current  |
A |
0.50 |
0.85" |
1.00 |
1.70" |
1.70 |
1.70 |
3.00 |
3.00 |
3.84 |
5.10" |
  Evaporator |
 Type |
  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger |
 |
  Freezing water Flow |
L/min |
25 |
41 |
73 |
83 |
93 |
118 |
158 |
187 |
235 |
316 |
Water pipe connection
|
mm |
25" |
25 |
32 |
32 |
32 |
40 |
40" |
50 |
50 |
65" |
Freezing Water Pump |
Type |
 High efficiency, low noise |
 |
Input Power
|
Kw |
0.37 |
0.55 |
0.75 |
0.75 |
1.10 |
1.10 |
1.50 |
1.50 |
2.20 |
2.20 |
Head |
m |
16 |
21 |
22 |
19 |
17 |
25 |
24 |
23 |
22 |
21 |
Refrigerant |
 Type |
 |
R22/R134A/R407C/R410A/R507/R404 |
 |
    Water tank Indicating Volume |
Liter |
70 |
75 |
100 |
115 |
145 |
250 |
270 |
320 |
360 |
400 |
Safety protection |
  high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc. |
 |
Dimensions (L*W*H) |
 Length |
mm |
1150 |
1150 |
1200 |
1350 |
1400 |
1600 |
1950 |
2100 |
2200 |
2450 |
Width |
mm |
560 |
560 |
850 |
850 |
850 |
1000 |
1250 |
1250 |
1250 |
1350 |
  High |
mm |
1120 |
1120 |
1550 |
1550 |
1550 |
1600 |
1600 |
1600 |
1850 |
2050 |
 Total Weight |
KG |
150 |
200' |
285 |
350' |
450 |
600 |
830 |
1050 |
1250 |
1350 |
Â
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.
Â
Company profile:
Winday Industrial is a professional R & D manufacturing and sales of industrial refrigeration equipment
and refrigeration system design, installation service company.
On behalf of product quality performance "efficient stability, progress energy efficiency."
Equipment manufacturing process to achieve excellence, strict control, strict examination;
Refrigeration program design to achieve repeated research, experiment, scrutiny, feasibility
studies and other processes,and strive to provide customers with an optimized cooling system integration solutions and equipment.
Contact Way:
Chiller Units For Machining Coolant Systems Flush
Â
Our products as follow:
3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller
Â
The Details of the chiller:
1.The Temperature Range:7ºC to -85ºC. Â
2.Cooling Capacity Range:
1RT to 1000RT
3.52kw to 3520kw
12010Btu to 12010240Btu
3027.2Kal to 3027200Kal
3. The Refrigerant:Â R22/R407c/R410a/R404a/R134a/R507c.
4.We can also produce the chiller according to your requirements.
One Parameter of our water chiller:
Air-cooled chiller parameters(output tem 7ºC)
Model |
 UNIT |
WD- |
 |
3AC/S |
5AC/S |
8AC/S
|
10AC/S
|
12AC/S
|
15AC/S
|
20AC/S
|
25AC/S
|
30AC/S
|
40AC/S
|
Cooling capacity |
Btu |
30026 |
49133 |
87006 |
98948 |
111572 |
140233.2 |
188684 |
223145 |
280466 |
377367 |
RT |
2.5 |
4.1 |
7.2 |
8.3 |
9.3 |
11.7 |
15.7 |
18.6 |
23.4 |
31.5 |
Kw |
8.8 |
14.4 |
25.5 |
29.0 |
32.7 |
41.1 |
55.3 |
65.4 |
82.2 |
110.6 |
×10³Kcal/h |
7.6 |
12.4 |
21.9 |
25.0 |
28.1 |
35.4 |
47.6 |
56.3 |
70.7 |
95.2 |
 Total Power |
KW |
3.1 |
5.2 |
8.1 |
9.5 |
10.9 |
14.4 |
19.3 |
20.5 |
28.6 |
38.0 |
Total Current |
A |
5.7 |
9.6 |
14.8 |
17.3 |
19.9 |
26.3 |
35.3 |
37.6 |
52.3 |
69.5 |
       Compressor |
 Qty |
set |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
2.00 |
2.00 |
2.00 |
Input power |
kw |
2.6 |
4.3 |
7.0 |
7.9 |
8.9 |
12.4 |
16.6 |
17.9 |
24.9 |
33.3 |
 Operation Current |
A |
4.6 |
7.6 |
12.4 |
14.0 |
15.9 |
22.1 |
29.6 |
31.8 |
44.3 |
59.2 |
Condenser |
Type |
Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger |
 |
Fans |
Input power |
kw |
0.19 |
0.42 |
0.38 |
0.84 |
0.84 |
0.84 |
1.14 |
1.14 |
1.50 |
2.52 |
Input Current  |
A |
0.50 |
0.85" |
1.00 |
1.70" |
1.70 |
1.70 |
3.00 |
3.00 |
3.84 |
5.10" |
  Evaporator |
 Type |
  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger |
 |
  Freezing water Flow |
L/min |
25 |
41 |
73 |
83 |
93 |
118 |
158 |
187 |
235 |
316 |
Water pipe connection
|
mm |
25" |
25 |
32 |
32 |
32 |
40 |
40" |
50 |
50 |
65" |
Freezing Water Pump |
Type |
 High efficiency, low noise |
 |
Input Power
|
Kw |
0.37 |
0.55 |
0.75 |
0.75 |
1.10 |
1.10 |
1.50 |
1.50 |
2.20 |
2.20 |
Head |
m |
16 |
21 |
22 |
19 |
17 |
25 |
24 |
23 |
22 |
21 |
Refrigerant |
 Type |
 |
R22/R134A/R407C/R410A/R507/R404 |
 |
    Water tank Indicating Volume |
Liter |
70 |
75 |
100 |
115 |
145 |
250 |
270 |
320 |
360 |
400 |
Safety protection |
  high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc. |
 |
Dimensions (L*W*H) |
 Length |
mm |
1150 |
1150 |
1200 |
1350 |
1400 |
1600 |
1950 |
2100 |
2200 |
2450 |
Width |
mm |
560 |
560 |
850 |
850 |
850 |
1000 |
1250 |
1250 |
1250 |
1350 |
  High |
mm |
1120 |
1120 |
1550 |
1550 |
1550 |
1600 |
1600 |
1600 |
1850 |
2050 |
 Total Weight |
KG |
150 |
200' |
285 |
350' |
450 |
600 |
830 |
1050 |
1250 |
1350 |
Â
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.
Â
Company profile:
Winday Industrial is a professional R & D manufacturing and sales of industrial refrigeration equipment
and refrigeration system design, installation service company.
On behalf of product quality performance "efficient stability, progress energy efficiency."
Equipment manufacturing process to achieve excellence, strict control, strict examination;
Refrigeration program design to achieve repeated research, experiment, scrutiny, feasibility
studies and other processes,and strive to provide customers with an optimized cooling system integration solutions and equipment.
Contact Way:
Feature editing
1, the pulse bag type Dust Collector [1] uses the split room pulsing pulsate cleaning technology to overcome the shortcomings of the conventional pulse duster and the chamber back duster. It has strong cleaning ability, high dust removal efficiency, low emission concentration, small air leakage rate, less energy consumption, less steel consumption, less area, stable and reliable transportation and good economic benefit. It is suitable for purification and recovery of dust gas in metallurgy, building materials, cement, machinery, chemical industry, electric power and light industry.
2. Due to the use of parting air pulse to blow the ash and blowing ash, it can reach the goal of thoroughly cleaning ash once, so the period of dust removal is prolonged, the energy consumption of ash clearing is reduced, and the air pressure consumption can be greatly reduced. At the same time, the fatigue degree of the filter bag and the pulse valve is reduced correspondingly, thus multiplying the service life of the filter bag and the valve piece.
3. Maintenance and replacement bags can be divided into chambers under the condition of continuous system blower and normal operation of the system. The bag bag mouth adopts elastic expansion ring, which has good sealing performance and firmness and reliability. The filter bag keel is polygonal, which reduces the friction between the bag and the keel, prolongs the life of the bag, and is convenient for unloading the bag.
4. The upper bag is adopted. After changing the bag, the bag is put out and the dirty bag is put into the bottom ash hopper of the box. It is removed by Kong Chu and improved the operation condition of the bag changing.
5. The box is designed with tightness, good sealing performance, good sealing material for inspection door, leak detection with kerosene in production process, and low leakage rate.
6. Inlet and outlet air duct is compact and airflow resistance is small.
Pulse Bag Collector
Pulse Bag Collector,Bag Filtering Dust Precipitator,Dusty Air Cleaning Equipment ,High Temperature Pulse Bag Collector
Botou Youjian Environmental Protection Equipment Co. LTD. , http://www.btdustmachine.com