Micropette Plus Autoclavable Pipette (Adjustable & Fixed)

Model NO.: HP-0007
Volume Range(UL): 0.1-2.5 and Others
Trademark: Dragon
Transport Package: Color Box with Export Carton
Specification: CE, ISO13485
Origin: Beijing, China
HS Code: 9018909000
Model NO.: HP-0007
Volume Range(UL): 0.1-2.5 and Others
Trademark: Dragon
Transport Package: Color Box with Export Carton
Specification: CE, ISO13485
Origin: Beijing, China
HS Code: 9018909000
Autoclavable Pipette (Adjustable & Fixed)

All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121ºC, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
 
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
   

Micropette Plus Autoclavable Pipette (Adjustable & Fixed)
 
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
 
Features for multi-channel MicroPette plus

- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
   
Calibration

Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation.
 
We will support and help you to achieve consistently excellent results.
 




Specifications
Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.1-2.5μL 0.05μL 2.5μL 2.50% 0.0625 2.00% 0.05
1.25μL 3.00% 0.0375 3.00% 0.0375
0.25μL 12.00% 0.03 6.00% 0.015
0.5-10μL 0.1μL 10μL 1.00% 0.1 0.80% 0.08
5μL 1.50% 0.075 1.50% 0.075
1μL 2.50% 0.025 1.50% 0.015
2-20μL 0.5μL 20μL 0.90% 0.18 0.40% 0.08
10μL 1.20% 0.12 1.00% 0.1
2μL 3.00% 0.06 2.00% 0.04
5-50μL 0.5μL 50μL 0.60% 0.3 0.30% 0.15
25μL 0.90% 0.225 0.60% 0.15
5μL 2.00% 0.1 2.00% 0.1
10-100μL 1μL 100μL 0.80% 0.8 0.15% 0.15
50μL 1.00% 0.5 0.40% 0.2
10μL 3.00% 0.3 1.50% 0.15
20-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
20μL 3.00% 0.6 1.00% 0.2
50-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
50μL 1.00% 0.5 0.40% 0.2
100-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
100μL 2.00% 2 0.70% 0.7
200-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
200μL 0.90% 1.8 0.30% 0.6
1000-5000μL 50μL 5000μL 0.50% 25 0.15% 7.5
2500μL 0.60% 15 0.30% 7.5
1000μL 0.70% 7 0.30% 3
2-10mL 0.1mL 10mL 0.60% 60 0.20% 20
5mL 1.20% 60 0.30% 15
2mL 3.00% 60 0.60% 12
8-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.5-10μL 0.1μL 10μL 1.50% 0.15 1.50% 0.15
5μL 2.50% 0.125 2.50% 0.125
1μL 4.00% 0.04 4.00% 0.04
5-50μL 0.5μL 50μL 1.00% 0.5 0.50% 0.25
25μL 1.50% 0.375 1.00% 0.25
5μL 3.00% 0.15 2.00% 0.1
50-300μL 5μL 300μL 0.70% 2.1 0.25% 0.75
150μL 1.00% 1.5 0.50% 0.75
50μL 1.50% 0.75 0.80% 0.4
12-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.5-10μL 0.1μL 10μL 1.50% 0.15 1.50% 0.15
5μL 2.50% 0.125 2.50% 0.125
1μL 4.00% 0.04 4.00% 0.04
5-50μL 0.5μL 50μL 1.00% 0.5 0.50% 0.25
25μL 1.50% 0.375 1.00% 0.25
5μL 3.00% 0.15 2.00% 0.1
50-300μL 5μL 300μL 0.70% 2.1 0.25% 0.75
150μL 1.00% 1.5 0.50% 0.75
50μL 1.50% 0.75 0.80% 0.4
Fixed Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
5μL - 5μL 1.3% 0.065 1.2% 0.06
10μL - 10μL 0.8% 0.08 0.8% 0.08
20μL - 20μL 0.6% 0.12 0.5% 0.1
25μL - 25μL 0.5% 0.125 0.3% 0.075
50μL - 50μL 0.5% 0.25 0.3% 0.15
100μL - 100μL 0.5% 0.5 0.3% 0.3
200μL - 200μL 0.4% 0.8 0.2% 0.4
250μL -- 250μL 0.4% 1.0 0.2% 0.5
500μL - 500μL 0.3% 1.5 0.2% 1.0
1000μL - 1000μL 0.3% 3.0 0.2% 2.0
2000μL - 2000μL 0.3% 6.0 0.15% 3.0
5000μL - 5000μL 0.3% 15 0.15% 7.5


Micropette Plus Autoclavable Pipette (Adjustable & Fixed)Micropette Plus Autoclavable Pipette (Adjustable & Fixed)
 
 
Autoclavable Pipette (Adjustable & Fixed)

All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

Fully autoclavable
 The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121ºC, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
 
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.
   

Micropette Plus Autoclavable Pipette (Adjustable & Fixed)
 
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
 
Features for multi-channel MicroPette plus

- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
   
Calibration

Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation.
 
We will support and help you to achieve consistently excellent results.
 




Specifications
Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.1-2.5μL 0.05μL 2.5μL 2.50% 0.0625 2.00% 0.05
1.25μL 3.00% 0.0375 3.00% 0.0375
0.25μL 12.00% 0.03 6.00% 0.015
0.5-10μL 0.1μL 10μL 1.00% 0.1 0.80% 0.08
5μL 1.50% 0.075 1.50% 0.075
1μL 2.50% 0.025 1.50% 0.015
2-20μL 0.5μL 20μL 0.90% 0.18 0.40% 0.08
10μL 1.20% 0.12 1.00% 0.1
2μL 3.00% 0.06 2.00% 0.04
5-50μL 0.5μL 50μL 0.60% 0.3 0.30% 0.15
25μL 0.90% 0.225 0.60% 0.15
5μL 2.00% 0.1 2.00% 0.1
10-100μL 1μL 100μL 0.80% 0.8 0.15% 0.15
50μL 1.00% 0.5 0.40% 0.2
10μL 3.00% 0.3 1.50% 0.15
20-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
20μL 3.00% 0.6 1.00% 0.2
50-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
50μL 1.00% 0.5 0.40% 0.2
100-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
100μL 2.00% 2 0.70% 0.7
200-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
200μL 0.90% 1.8 0.30% 0.6
1000-5000μL 50μL 5000μL 0.50% 25 0.15% 7.5
2500μL 0.60% 15 0.30% 7.5
1000μL 0.70% 7 0.30% 3
2-10mL 0.1mL 10mL 0.60% 60 0.20% 20
5mL 1.20% 60 0.30% 15
2mL 3.00% 60 0.60% 12
8-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.5-10μL 0.1μL 10μL 1.50% 0.15 1.50% 0.15
5μL 2.50% 0.125 2.50% 0.125
1μL 4.00% 0.04 4.00% 0.04
5-50μL 0.5μL 50μL 1.00% 0.5 0.50% 0.25
25μL 1.50% 0.375 1.00% 0.25
5μL 3.00% 0.15 2.00% 0.1
50-300μL 5μL 300μL 0.70% 2.1 0.25% 0.75
150μL 1.00% 1.5 0.50% 0.75
50μL 1.50% 0.75 0.80% 0.4
12-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.5-10μL 0.1μL 10μL 1.50% 0.15 1.50% 0.15
5μL 2.50% 0.125 2.50% 0.125
1μL 4.00% 0.04 4.00% 0.04
5-50μL 0.5μL 50μL 1.00% 0.5 0.50% 0.25
25μL 1.50% 0.375 1.00% 0.25
5μL 3.00% 0.15 2.00% 0.1
50-300μL 5μL 300μL 0.70% 2.1 0.25% 0.75
150μL 1.00% 1.5 0.50% 0.75
50μL 1.50% 0.75 0.80% 0.4
Fixed Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
5μL - 5μL 1.3% 0.065 1.2% 0.06
10μL - 10μL 0.8% 0.08 0.8% 0.08
20μL - 20μL 0.6% 0.12 0.5% 0.1
25μL - 25μL 0.5% 0.125 0.3% 0.075
50μL - 50μL 0.5% 0.25 0.3% 0.15
100μL - 100μL 0.5% 0.5 0.3% 0.3
200μL - 200μL 0.4% 0.8 0.2% 0.4
250μL -- 250μL 0.4% 1.0 0.2% 0.5
500μL - 500μL 0.3% 1.5 0.2% 1.0
1000μL - 1000μL 0.3% 3.0 0.2% Carbon Desorption1

Compared with similar products at home and abroad, this series of equipment has significant technical advantages, which are mainly reflected in:

1. High gold desorption rate: the carbon-poor gold grade after desorption is less than or equal to 50g/t (the same industry products are generally less than or equal to 100g/t).

2. High primary electrolysis rate: the average electrolysis rate of desorption solution is ≥90%. (The products in the same industry are generally around 70%).

3. Accurate gold balance: the actual amount of gold obtained after desorption and electrolysis is consistent with the theoretical gold content in the gold-loaded carbon. (Products in the same industry generally have the phenomenon of "floating gold or accumulative funds", which causes the loss of gold in the processing process and makes the amount of gold unbalanced)

4. Efficient and easy to operate: The whole set of equipment adopts integrated design, signal acquisition, operation adjustment control and safety protection are automated to ensure high efficiency, easy operation, safety and reliability during the entire operation period.

5. Low operating cost: The equipment is made of real materials of special materials (mainly including high-quality insulation materials, all-tetrafluoroethylene insulation materials, fully imported aerospace-grade circulating pumps, high-resistance electric shock heating pipes, etc.). The power-consuming equipment adopts frequency conversion design to ensure the low cost of operation and maintenance while ensuring the desorption electrolysis index.

Carbon Desorption1,Electrolytic Refining Of Gold,Gold Mining Machine,Extraction Of Gold,Electrowinning For Gold

Changchun Gold Research Institute Co.LTD , https://www.changchunmachine.com